Buy & Amber Loose Lay Heating Cable For Timber/Concrete Floors Online

T: 01604 439300
E: [email protected]
Mon-Fri: 07:15 - 19.00
Sat: 08.00 - 12.00
Tools & Trim
  • Free UK delivery
    on most orders over £250 net*
  • Worldwide delivery
     
  • Finance Available
    on orders over £250
 

Amber Loose Lay Heating Cable For Timber/Concrete Floors

Quick And Easy To Install

4-Metre Cold Tail

4mm Cable Thickness

2 Studs = 156W/m²
3 Studs = 104W/m²

100% Aluminium Earth Shield

10W/m @230V Output

Choice Of Size

Product Name
Price (ex)
Price (inc)
Options
Info
Description
Specification
Attachments

The Amber cable is an extremely high-quality, 360° fully screened twin conductor cable with a tough yellow PVC outer sheath (non-UV stable).   Its round profile, robust construction and low height ensure a fast, simple and safe installation which is perfect for renovating existing floors.

The cold lead is an installation cable with solid conductors ensuring fast installation. A clearly visible connection avoids accidentally installing the heated cable in the wall.

Tile / Stone:

Fully encapsulate the Amber Heating Cable with either a flexible smoothing compound or flexible tile adhesive, prior to the tile/floor finish being laid. Amber recommends the use of a plastic trowel when laying tile adhesive, to protect the underfloor heating cable from accidental damage.

Carpet:

Fully encapsulate the Amber Heating Cable with a flexible smoothing compound, to provide a minimum of 10mm coverage above the top of the heating cable, prior to the carpet floor finish being laid. Avoid rubber or foam-backed carpets. Please check with the carpet manufacturer to ensure the carpet is suitable for underfloor heating.

Timber:

Fully encapsulate the Amber Heating Cable with either a 6-7mm bed of flexible smoothing compound layer, prior to the timber floor finish being laid. When installing natural wood floors it is recommended that softwood floors should not exceed 20mm in thickness, hardwood floors should not exceed 30mm in thickness.

Vinyl:

Fully encapsulate the Amber Heating Cable with a 10mm bed of flexible smoothing compound, to provide a minimum of 5mm coverage above the top of the heating element, prior to the vinyl floor finish being laid. 

*Floor coverings should not exceed a thermal resistance of 0.15 m²K/W. Please note that thermally resistive items should not be left or installed onto the underfloor heating in a way where heat can become trapped. This trapped heat could cause failure if left without due care or attention. Possible examples of thermal restrictive items could be heavy rugs, bean bags or a mattress laid in direct contact with the floor. Some items of furniture that do not allow airflow could also cause concern.

Operation Voltage: 220-240v~
Construction: Round Twin Conductor With 360º Screening, One Cold Tail
Output: 10W/m @230V~
Max. Permissible Use Temperature, Powered: 85º C
Cable Thickness: 4mm
Deformation Strength: 600N
Pulling Strength: 120N
Conductor Insulation: FEP
Outer Sheath: PVC
Screen, 100% coverage, alu foil, 0.5mm² tinned copper drain wire
Cold Lead: 4m DTWB, 2x 1.0mm², Earthed
Min Installation temp: -5ºC
Bending Radius: 6 X Ø
IP CLASS: IPX7